The Megger MIT1020-2 is a 10 kV diagnostic insulation resistance tester for high voltage electrical equipment including motors, generators, transformers, cables, and switchgear. It measures insulation resistance up to 35 TΩ, giving you actual trending values instead of ambiguous “infinity” readings, and runs five automatic test programmes: IR, PI, DAR, SV, and DD. IEEE 43-2000 recommends 10 kV test voltage for motor windings rated above 12 kV, and the MIT1020-2 delivers exactly that.
Key specifications
The MIT1020-2 offers continuously variable test voltage from 50 V to 10 kV, covering low voltage cable testing through to high voltage motor diagnostics with a single instrument. The large backlit analog/digital LCD display reads clearly in bright sunlight and poorly lit substations alike, showing resistance, voltage, leakage current, capacitance, battery status, and time constant simultaneously.
| Parameter | Specification |
| Test voltage range | 50 V to 1 kV in 10 V steps; 1 kV to 10 kV in 25 V steps |
| Insulation resistance range | 10 kΩ to 35 TΩ (digital); 100 kΩ to 1 TΩ (analog) |
| Accuracy (23 °C, 10 kV) | ±5% to 1 TΩ; ±20% to 20 TΩ |
| Short circuit current | 3 mA |
| Current measurement | 0.01 nA to 5 mA |
| Capacitance measurement | 10 nF to 50 µF (above 500 V) |
| Guard terminal | 2% error guarding 500 kΩ leakage with 100 MΩ load |
| Test programmes | Auto IR, PI, DAR, SV, DD |
| Memory and interface | 32 kB onboard; RS232 and USB download |
| Power supply | Mains (95 to 240 V AC) or rechargeable battery (approx. 4 hours at 10 kV) |
| Safety rating | CAT IV 600 V per EN 61010-1; impulse protection to 8 kV |
| Ingress protection | IP65 (lid closed) |
| Operating temperature | -20 °C to +50 °C |
| Weight | Approx. 7.1 kg |
| Dimensions | 305 x 194 x 360 mm |
The 3 mA short-circuit current charges capacitive loads faster than lower-output insulation testers, which matters on long cable runs and large motor windings where charge times can stretch into minutes.
Diagnostic test modes
The PI (polarization index) test gives you the 10-minute to 1-minute IR ratio that IEEE 43-2000 calls for when assessing moisture or contamination in motor windings. DAR (dielectric absorption ratio) offers a quicker field screening alternative. SV (step voltage) applies increasing test voltage to expose voltage-dependent insulation weaknesses that a single-voltage spot test would miss. DD (dielectric discharge) measures charge released after the test voltage is removed, detecting thermal damage in multi-layer insulation systems.
A selectable breakdown/burn mode and adjustable alarm limit setting handle more specific diagnostic scenarios. Test results store onboard and download via USB or RS232 to Megger Download Manager software for record-keeping free of transposition errors.
Safety and build quality
The CAT IV 600 V safety rating protects for use at mains origin and upstream of main distribution, a significant upgrade from the original MIT1020’s CAT III 300 V. If accidentally connected to a live circuit, external voltage is displayed and testing is inhibited above 80 V. Capacitive loads discharge automatically at the end of any test.
The rugged polypropylene case achieves IP65 with the lid closed. A quick-start guide printed inside the lid means you do not need to carry the manual to site. The guard terminal is included as standard, providing accurate measurement even where surface leakage is present. Dual power operation (mains or battery) means you can test wherever the job takes you; mains operation also provides enhanced charging capability for high-capacitance test samples.
Why buy from Powerpoint Engineering
We have been the authorised Megger distributor in Ireland since 1996. Our INAB-accredited calibration laboratory calibrates insulation resistance testers with certificates traceable to national standards, and our Achilles Level 3 registration covers procurement compliance for utility and semi-state buyers.
Request a quote online or call us on 057 866 2162 for MIT1020-2 pricing, stock availability, and technical advice.
Frequently asked questions
What is the difference between the Megger MIT1020-2 and the MIT1025?
The Megger MIT1025 is a newer model in the Megger 10 kV insulation tester range, using lithium-ion battery technology for a lighter, faster-charging instrument with added ramp test functionality. The MIT1020-2 offers a higher measurement range at 35 TΩ and remains a proven workhorse for high voltage insulation diagnostics.
Does the MIT1020-2 comply with IEEE 43-2000?
Yes. IEEE 43-2000 recommends 10 kV test voltage for motor windings rated above 12 kV. The MIT1020-2 provides variable test voltage from 50 V to 10 kV and includes automatic PI testing as specified in the standard.
Can the MIT1020-2 run on battery power?
Yes. It operates on mains power (95 to 240 V AC) or its internal rechargeable battery, which provides approximately 4 hours of continuous testing at 10 kV with a 100 MΩ load.
We are the authorised Megger distributor in Ireland. Download the Megger MIT1020-2 datasheet for full specifications, or call our technical team on 057 866 2162 to request a quote.
Megger MIT1020-2 10kV Insulation Resistance Tester Datasheet
For additional technical details about the Megger MIT1020-2 10kV Insulation Resistance Tester please refer to the product datasheet.
Megger MIT1020-2 10kV Insulation Resistance Tester User Manual
Please click on the button to Download the Megger MIT1020-2 10kV Insulation Resistance Tester User Manual.